Enphase HCS-40 with COSMOS and ChargeGuard: Difference between revisions

From EV Charger Wiki
No edit summary
Line 69: Line 69:
| '''FEATURES''' ||
| '''FEATURES''' ||
|-  
|-  
| Four LED indicators || Amber LED: Power, Green LED: Charging, 1st Red LED: Power fault, 2nd Red LED: Charging fault
| Four LED indicators || Amber LED: Power, Green LED: Charging, 1st Red LED: Power Fault, 2nd Red LED: Charging Fault — provides quick, clear status feedback and easy diagnostics.
|-  
|-  
| Smart Scheduling || Enables time-of-use charging to optimize energy costs by charging during off-peak utility hours
| ChargeGuard Access Control || Key-based system allows only authorized users to start charging, ensuring security in shared or commercial environments
|-
|-
| Self-Consumption || Allows charging with clean solar energy when integrated with an Enphase Energy System for sustainable performance
| COSMOS Integration || Enables seamless integration with building energy management or third-party monitoring systems for advanced control and power optimization
|-  
|-  
| Main Panel Upgrade Avoidance || Supports EVSE dynamic power management (PCS-LC and UL 3141 certified) to prevent overloading the main electrical panel
| Digital Load Management || Offers four selectable power levels (100%, 50%, 25%, and 0%) to support dynamic energy distribution and load balancing
|-  
|-  
| Storm Guard || Ensures the EV remains fully charged and ready whenever a storm alert is detected in the area
| UART Serial Communication || Provides advanced interface for developers with five adjustable power levels and detailed station monitoring capability
|-  
|-  
| Remote Start/Stop || Provides remote control access through the Enphase app to start or stop charging conveniently and securely
| Vehicle and Station Monitoring || Tracks vehicle connection, station activity, and EVSE diagnostic information remotely for improved operational visibility
|-  
|-  
| Connectivity || Equipped with Wi-Fi 2.4 GHz and Bluetooth for reliable wireless communication and seamless setup
| Automatic Circuit Reclosure || Automatically restarts charging after minor power faults, maintaining continuous performance without manual intervention
|-  
|-  
| Integration Support || Compatible with OCPP 1.6 protocols and Enphase APIs for flexible third-party and system integrations.
| Cable Management System || Includes a 25 ft cable with an integrated wrap and wall-mounted holster to keep equipment tidy and off the ground
|-  
|-  
| '''Warranty''' || 5-year
| '''Warranty''' || 5-year
Line 89: Line 89:
| '''User Rating''' || N/A
| '''User Rating''' || N/A
|-
|-
| '''Price''' || $1,024
| '''Price''' || $1,275
|}
|}



Revision as of 11:30, 26 October 2025

Enphase HCS-40 with COSMOS and ChargeGuard

The Enphase HCS-40 with COSMOS and ChargeGuard combines reliability, security, and advanced integration for commercial EV charging. This 32 A Level 2 charger is engineered for seamless communication with building energy management systems through COSMOS technology, enabling power monitoring and load control with precision.

Constructed with a rugged NEMA 4-rated enclosure, the HCS-40 ensures dependable operation indoors or outdoors under any condition. The ChargeGuard key-access system adds security and usage control, while the 25 ft cable with a cable wrap and holster ensures organized storage and extended reach for high-traffic installations.

Charging Speed

The Enphase HCS-40 with COSMOS and ChargeGuard delivers up to 7.7 kW of charging power, adding approximately 31 miles of driving range per hour of charge time.
Enphase HCS-40 EV Charger with ChargeGuard 01.png

Technical Specifications

ELECTRICAL SPECIFICATIONS
Charging power 32 A (7.7 kW) max.
Input voltage/Input voltage range 208/240 VAC (L-L), single-phase/185 VAC – 264 VAC
Input voltage frequency 50/60 Hz
Circuit breaker requirement Dedicated, 2-pole 40 A
Input cable type Pre-wired with: (L1, L2, Gnd) 10 AWG service whip / Pre-wired with: NEMA 14-50P
Input cable length
  • 3' (914.4 mm)
  • 12" (304.8 mm)
Maximum output current/Output power 32 A continuous/7.7 kW
Output cable/Cable length Pre-wired with SAE J1772/25' (7.6 m) or 18' (5.5) 1
MECHANICAL DATA
Enclosure mounting Wall or pedestal mounted (pedestal sold separately)
Enclosure dimensions (L × W × D) 19.7" × 8.9" × 5.3" (500 mm × 226 mm × 135 mm)
Weight 13.5 lbs. (6.1 kg)
ENVIRONMENTAL SPECIFICATIONS
Enclosure rating NEMA Type 4 - watertight
Environment rating Indoor/outdoor rated
Operating / Storage temperature -22°F to 122°F (-30°C to 50°C)/-40°F to 176°F (-40°C to 80°C)
COMPLIANCE SPECIFICATIONS
Codes and standards NEC Article 625, SAE J1772, ENERGY STAR®, UL, NOM
Safety compliance
  • UL 2594, UL 2251, UL 2231-1, UL 2231-2, UL 1998, UL 991
  • C22.2 No. 280-13, CSA C22.2 No. 282, CSA C22.2 No. 281.1, CSA C22.2 No. 281.2, CSA C22.2 No. 0.8
  • NOM-001-SCFI-2018
EMC compliance FCC Part 15 Class B
Short-circuit protection 5000 RMS Symmetrical Amps at 240 VAC
Open safety ground detection Features a continuous earth ground monitor to ensure consistent connection to good earth ground
Ground fault detection Ground fault protection integral, CCID 20 mA, auto reset
Auto-reclosure System will automatically resume standard operation after a minor power fault has cleared
FEATURES
Four LED indicators Amber LED: Power, Green LED: Charging, 1st Red LED: Power Fault, 2nd Red LED: Charging Fault — provides quick, clear status feedback and easy diagnostics.
ChargeGuard Access Control Key-based system allows only authorized users to start charging, ensuring security in shared or commercial environments
COSMOS Integration Enables seamless integration with building energy management or third-party monitoring systems for advanced control and power optimization
Digital Load Management Offers four selectable power levels (100%, 50%, 25%, and 0%) to support dynamic energy distribution and load balancing
UART Serial Communication Provides advanced interface for developers with five adjustable power levels and detailed station monitoring capability
Vehicle and Station Monitoring Tracks vehicle connection, station activity, and EVSE diagnostic information remotely for improved operational visibility
Automatic Circuit Reclosure Automatically restarts charging after minor power faults, maintaining continuous performance without manual intervention
Cable Management System Includes a 25 ft cable with an integrated wrap and wall-mounted holster to keep equipment tidy and off the ground
Warranty 5-year
User Rating N/A
Price $1,275

Smart Features of Enphase HCS-40 with COSMOS and ChargeGuard

  • COSMOS Integration Technology: Enables communication with building management and energy systems for real-time monitoring, data sharing, and intelligent energy use optimization.
  • Dual Communication Interfaces: Includes Digital Load Management and UART Serial Communication for flexible integration with third-party control or monitoring systems.
  • Power Level Adjustment: Offers four to five programmable power settings (100%, 75%, 50%, 25%, 0%) for efficient energy distribution and load balancing.
  • Status Monitoring Capability: Displays live EVSE and vehicle connection status, allowing remote diagnostics and performance visibility through management systems.
  • External LED Support: Allows control of up to two user-supplied LEDs for real-time visual indication of charging and fault conditions.
  • ChargeGuard Access Control: Provides key-based access to limit charging to authorized users, ensuring secure operation in shared or commercial spaces.

Enphase HCS-40 EV Charger with ChargeGuard 02.jpeg

Product guides and documents of Enphase HCS-40 with COSMOS and ChargeGuard

Enphase HCS-40 EV Charger with ChargeGuard product Manual Sheet

Enphase HCS-40 EV Charger with ChargeGuard product Technical Specification Sheet

Advantages of the Enphase - Enphase HCS-40 with COSMOS and ChargeGuard

  • Commercial-Grade Performance: Designed for business environments requiring reliable, high-traffic EV charging with robust system control.
  • Seamless System Integration: COSMOS technology simplifies connection to energy management or building automation systems for advanced monitoring.
  • Enhanced Security: ChargeGuard ensures only authorized personnel can access charging, ideal for workplace or fleet applications.
  • Weatherproof Design: Fully sealed NEMA 4 enclosure offers superior protection against dust, moisture, and temperature extremes.
  • Flexible Cable Management: Integrated 25 ft cable wrap and holster keep equipment neatly organized and damage-free.
  • Certified Safety Compliance: ETL, cETLus, and ENERGY STAR® certified for exceptional efficiency and safety standards.

Disadvantages of the Enphase Enphase HCS-40 with COSMOS and ChargeGuard

  • Hardwired Installation: Requires a professional setup, increasing installation complexity compared to plug-in chargers.
  • No Wi-Fi or Bluetooth: Lacks wireless connectivity for smartphone control or remote management through apps.
  • Technical Setup Required: COSMOS integration may need specialized knowledge or IT assistance for configuration.
  • Business-Oriented Design: Overbuilt for residential needs, making it better suited for commercial properties.
  • Fixed Mounting Design: Permanent installation limits relocation flexibility.
  • Higher Initial Cost: Advanced integration features contribute to a higher purchase price than basic Level 2 models.

Where to buy